NET-PwrCtrl HUT EX
|
|
Characteristics: | HUT-EX - LV-P | HUT-EX - HV-P | HUT-EX - LV-S | HUT-EX - HV-S |
Relay | 8 | 8 | 8 | 8 |
Input | 8 | 8 | 8 | 8 |
Max. control (input) voltage. | 12V- | |||
Rated voltage power supply. | 8-30V~ 10-40V- |
100-240V~ 50-60Hz |
8-30V~ 10-40V- |
100-240V~ 50-60Hz |
Power Consumption | 1,6 W | 3,0 W | 1,6 W | 3,0 W |
Max. Load each relay |
16A/250V~ (resistive load) 16A/14- TÜV R50126372 |
|||
Terminals I/O | AK4101 | AK4101 | AK4101 | AK4101 |
Terminals relay | AK4101 | AK4101 | AKZ700 | AKZ700 |
Terminals AK4101 | Connection cross sections | |||
Solid | 0,08 mm²-2,5 mm² | |||
Stranded (flexible) | 0,5mm²-1,5 mm² | |||
Stranded with Ferrule | 0,14 mm²-1,0 mm² | |||
Ratings | VDE 250V 17,5A Test Voltage 2,0 kV |
|||
Terminals AKZ700 | Connection cross sections | |||
Solid | 0,2 mm² - 4,0 mm² | |||
Stranded (flexible) | 0,2 mm² - 2,5 mm² | |||
Stranded with Ferrule | 0,25 mm² - 2,5 mm² | |||
Ratings | VDE 250V 24A Test Voltage 2,0 kV |
|||
Dimensions | L 106,5 B 95 H 63mm 6 Fuses wide 35mm DIN rail |
|||
Temperature range | -20°C...+60°C | |||
Humidity | 10 ... 90% not condensed | |||
Delivery | NET-PwrCtrl HUT EX, IO-Cable. | |||
Description as PDF | ||||
HUT-EX - LV-P | HUT-EX - HV-P | HUT-EX - LV-S | HUT-EX - HV-S | |
Online Shop | ||||